Emptying The Boiler; Faults; Disposal - Sime ECOMAXI 260 ErP Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

empty the water in the boiler (see
section 8.6);
unscrew the top anode and check for
any corrosion; if more than 30% of the
anode surface is corroded, replace the
anode;
repeat for the bottom anode.
The anodes have a gasket; to avoid water
leakages, use an anaerobic sealant for
compatible threads for use in heating and
sanitation systems. The gaskets should be
replaced both during checks and when
replacing anodes with new gaskets.
8.6

Emptying the boiler

If the boiler is not used, especially in low
temperatures, it is good practice to empty
the water inside the boiler.
For this appliance, simply disconnect the
water inlet connector (see section 5.4).
Alternatively, when setting up the system,
install a drain valve with a hose connector
coupling.
NOTE: remember to empty the
system when temperatures are
low to prevent freezing.

9 Faults

Should you notice anything unusual as
regards appliance operation, without there
being an alarm or error code as described
in the relevant parts of this manual, check
whether the problem is easily resolvable by
consulting
the
table
contacting technical support.
below,
before
DOCUMENT 6328408
Installation, use and maintenance manual
Fault
The heat pump does
not turn on
The compressor or
fan
are
not
activated
The heat pump is
activated
and
deactivated
repeatedly
The
heat
pump
remains active and
never switches off
The electrical resistor
does not turn on
WARNING: should you not be
able to solve the problem, turn
the appliance off and contact
the technical support service,
specifying the appliance model
you have purchased.

10 Disposal

At the end of their life, the heat pumps
should be disposed of in line with the
regulations in force.
WARNING:
contains fluorinated greenhouse
gases included under the Kyoto
Protocol.
disposal must only be carried out
by qualified personnel.
Possible causes
There
is
no
electricity;
The
plug
is
not
plugged
into
the
socket properly
The
pre-set
safety
time has not passed
yet
The
programmed
temperature
has
been reached
Incorrect
programming
of
parameters/ setpoint
values/ differentials
Incorrect
programming
of
parameters/ setpoint
values/ differentials
It does not need to
turn on
this
appliance
Maintenance
and
75

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecomaxi 260 s erp81158208115821

Table des Matières