Using The Boiler Brava One Of; Control Panel - Sime Brava One 25 OF Manuel Pour L'utilisation, L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1

USING THE BOILER BRAVA ONE OF

1.1

Control panel

2
2
1
1
KNOBS
t
The heating knob allows the user to set the heating tem-
perature to between 20 and 80°C during normal opera-
tion.
r
The domestic hot water knob allows the user to set the
domestic hot water temperature to between 10 and 60°C
during normal operation.
FUNCTIONAL BUTTONS
2
s
If pressed once or more than once for at least 1 second
during normal operation, this button allows the user to
change the boiler operating mode in a cyclical sequence
(Stand-by – Summer – Winter).
<
This allows the user to scroll through the parameters or
decrease the values.
>
This allows the user to scroll through the parameters or
increase the values.
o
This allows the user to confirm the selected parame-
ter or to modify the value or to "unblock" the appliance
when the alarm for a "block" malfunction is present.
c
Programming connector cover plug.
44
3
2
2
1
2
Fig. 1
pressing any one of these buttons for more than 30 sec-
NOTE:
onds generates a fault on the display without preventing boiler
operation. The warning disappears when normal conditions are
restored.
DISPLAY
3
l
. This symbol appears when the boiler is oper-
"SUMMER"
ating in Summer mode or if only the domestic hot water
mode is enabled via the remote control. If the symbols
l
and
n
are flashing, this indicates that the chimney
sweep function is active.
n
. This symbol appears when the boiler is oper-
"WINTER"
ating in Winter mode or if both the domestic hot water
and heating modes are enabled via the remote control.
With the remote control, if no operating modes have
been enabled both symbols
R
"RESET REQUIRED"
. This message only appears if there
is a malfunction which must be or may be restored man-
ually.
r
"DOMESTIC HOT WATER"
a request for DHW or when the chimney sweep function
is operating; it flashes during the domestic hot water set
point selection.
t
. This symbol is present during heating oper-
"HEATING"
ation or when the chimney sweep function is operating;
it flashes during the heating set point selection.
f
"BLOCK" DUE TO NO FLAME
F
.
"FLAME PRESENCE"
K
. This indicates that a fault has occurred. The
"ALARM"
number specifies the cause which generated the alarm
(see paragraph "Fault / malfunction codes".
H
"MAINTENANCE REQUEST"
perform maintenance on the boiler.
EN
l
and
n
will be off.
. This symbol is present during
.
. If active, it shows it is time to

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

81121808112181

Table des Matières