1
USING THE BOILER BRAVA SLIM BF
1.1
Control panel
1
FUNCTIONAL BUTTONS
1
y
If pressed once or more than once for at least 1 second
during normal operation, this button allows the user to
change the boiler operating mode in a cyclical sequence
(Stand-by – Summer – Winter). If the boiler is experienc-
ing a fault which can be reset, it allows boiler operation to
be unblocked.
r
During normal operation, pressing the button displays
the domestic hot water set point which can be between
10 and 60°C. In "parameter setting", the user can scroll
through the parameter index (decreasing) by pressing
this button.
t
During normal operation, pressing the button displays
the heating set point which can be between 20 and 80°C.
In "parameter setting", the user can scroll through the
parameter index (increasing) by pressing this button.
<
During normal operation, pressing this button allows the
user to reduce the heating or DHW set point on the basis
of the selection made previously. If there is a Remote Con-
trol (Open Therm), after having selected the heating but-
ton, the user can modify the incline of the climatic curve
(decreasing it) by pressing the button ( - ). In "parameter
setting/display", the user can modify the parameter set-
ting or value (decreasing) by pressing this button.
>
During normal operation, pressing this button allows the
user to increase the heating or DHW set point on the basis
of the selection made previously. If there is a Remote Con-
trol (Open Therm), after having selected the heating but-
ton, the user can modify the incline of the climatic curve
(increasing it) by pressing the button ( + ). In "parameter
setting/display", the user can modify the parameter set-
ting or value (increasing) by pressing this button.
48
2
Fig. 1
c
Programming connector cover plug.
pressing any one of these buttons for more than 30 sec-
NOTE:
onds generates a fault on the display without preventing boiler
operation. The warning disappears when normal conditions are
restored.
2
DISPLAY
l
"SUMMER"
. This symbol appears when the boiler is oper-
ating in "Summer" mode or if only the domestic hot water
mode is enabled via the remote control. If the symbols
l
and
n
are flashing, this indicates that the chimney
sweep function is active.
n
. This symbol appears when the boiler is oper-
"WINTER"
ating in "Winter" mode or if both the domestic hot water
and heating modes are enabled via the remote control.
With the remote control, if no operating modes have been
enabled both symbols
d
. The message indicates that after
"RESET REQUIRED"
having repaired the fault, normal boiler operation can be
restored by pressing the button
r
"DOMESTIC HOT WATER"
DHW request or during the "chimney sweep function" It
flashes during the selection of the domestic hot water set
point.
t
"HEATING"
. This symbol lights up during heating opera-
tion or during the "chimney sweep function It flashes dur-
ing the selection of the heating set point.
f
"BLOCK" DUE TO NO FLAME
F
"FLAME PRESENCE"
.
v
. This indicates the power level at which
"POWER LEVEL"
the boiler is operating.
p
. This indicates that the user may be in pa-
"PARAMETER"
rameter setting/display, or "info" or "counter", or in "acti-
vated alarms" (history).
A
. This indicates that a fault has occurred. The
"ALARM"
number specifies the cause which generated the alarm.
z
. This indicates that the "chimney
"CHIMNEY SWEEP"
sweep function" has been activated.
a
"HEATING SYSTEM PRESSURE"
pressure.
E
"ECO", ALTERNATIVE ENERGY SOURCES
indicates that there is a solar system available.
c
"MAINTENANCE REQUEST"
perform maintenance on the boiler.
EN
l
and
n
will be off.
y
.
. This symbol is present during a
.
. Display of heating system
. Where active, it
. If active, it shows it is time to