Sime ECOMAXI 260 ErP Manuel D'installation, D'utilisation Et D'entretien page 55

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pos.
Description
Cold water inlet
Hot water output
Condensate outlet
Recirculation
Coil for solar thermal
input
Sensor socket (only for
relevant models)
Fig. 7 – Plumbing connections
The figure below(Fig. 8) shows an example
of a plumbing hook-up.
Connector/hole
1"G
1"G
½"
¾"G
1"
G
1/4
½"G
 Water input;
 Isolation valve
 Automatic thermostatic mixing device
 Heat pump
 Recirculation pump
Spring-loaded check valve
 Hot water output
 Relief valve
 Drain tube inspectable end
 Drain valve
DOCUMENT 6328408
Installation, use and maintenance manual
Val
ve
Expansion vessel
Fig. 8 – Example of a water system set-up
Connection
to boiler
Fig. 8a – Example of heavy-series relief valve
NOTE: an impurities filter must be
installed on the cold water inlet.
The appliance must not operate
with water with a hardness below
12°F, or vice versa with extremely
hard
water
suitably
calibrated
monitored softener should be
used in this case, but the residual
hardness should not fall below
15°F.
Cold water
input
Connection to
outlet siphon
(above
25°F).
A
and
55

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecomaxi 260 s erp81158208115821

Table des Matières