Description of parameter
Delay from last ON
Delay from last OFF
Minimum time ON
Number of compressor operating hours for
maintenance request
Air temperature reading delay for cold
evaporator test
Minimum delay between fan ON and
compressor activation to check incoming
air temperature
Timeout for solar thermal cycle
Delay for faulty fan check
Type of defrosting
Evaporator temperature for defrosting stop
(only where P4 = 1)
Maximum defrosting duration
Threshold for automatic defrosting start
(evaporator temperature)
Minimum compressor ON time for
defrosting start
Minimum alarm probe (only AL1
notification)
Minimum alarm setpoint (only AL1
notification)
Minimum alarm delay type (only AL1
notification)
Maximum alarm probe (only AH
notification)
Maximum alarm setpoint (only AH
notification)
Maximum alarm delay type (only AH
notification)
AL1 minimum alarm delay from appliance
on (notification only)
AL1 and AH temperature alarm delay (only
notification)
Alarm differential
Resistor ON interval (anti-legionella)
Anti-legionella function setpoint
Anti-legionella function duration
Enable solar thermal input (digital 1)
Installation, use and maintenance manual
Abbre
Unit
min
viation
C1
min
0
C2
min
0
C3
sec
0
C10
h
0
C11
min
0
C12
min
0
C13
min
0
C14
min
-1
d1
----
0
d2
°C/°F
-50.0
d3
min
0
d17
°C/°F
-50.0
d18
min
0
A0
----
0
A1
°C/°F
0.0
A2
----
0
A3
----
0
A4
°C/°F
0.0
A5
----
0
A6
min
0
A7
min
0
A11
min
0.1
H0
Days
0
H1
°C/°F
10.0
H3
min
0
i0
----
0
DOCUMENT 6328408
Max.
Default Notes
240
5
240
5
240
0
9999
1000
0 = function excluded
999
120
240
1
240
20
240
20
-1 = function disabled
0 = with resistors
2
1
1 = hot gas
2 = compressor stop
50.0
3.0
99
8
50.0
-2.0
240
60
0 = upper probe
2
0
1 = lower probe
2 = evaporator probe
50.0
10.0
0 = Disabled
1
0
1 = Absolute
0 = upper probe
2
0
1 = lower probe
2 = evaporator probe
199.0
90.0
0 = Disabled
1
0
1 = Absolute
240
120
240
15
30.0
2.0
99
30
199.0
70.0
240
2
0 = input disabled
2
2
1 = pressure input
2 = digital 1 input
71