2.4.5 Time Weighted Average (TWA Page)

If the TWA alarm activates, leave the contaminated area
immediately; the ambient gas concentration has reached
the preset TWA alarm level. Failure to follow this warning
will cause over-exposure to toxic gases and persons
relying on this product for their safety could sustain
serious personal injury or death.
This page shows the average exposure over 8 hours since the
instrument was turned ON or the TWA reading was reset. When the
amount of gas detected by the instrument is greater than the TWA limit:
MONOCHROME DISPLAY
TWA
Alarm sounds
Alarm lights flash
"TWA ALARM" message flashes.
To Reset the TWA Readings
1. Access the TWA page.
2. Press the
The TWA alarm is calculated over an eight-hour exposure.
TWA Calculation Examples:
1-hour exposure of 50 ppm:
(1 hour x 50 PPM) + (7 hours x 0 PPM)
4-hour exposure of 50 ppm and
4-hour exposure of 100 ppm:
(4 hours x 50 PPM) + (4 hours x 100 PPM)
12-hour exposure of 100 ppm:
(12 hours x 100 PPM)
This page can be de-activated through MSA Link software.
! WARNING
button.
8 hours
8 hours
8 hours
COLOR DISPLAY
= 150 PPM
= 6.25 PPM
= 75 PPM