sensor and reduce its readings:
Organic silicones
Silicates
Lead-containing compounds
Sulphur compound exposures over 200 ppm or exposures over
50 ppm for one minute.
The minimum concentration of a combustible gas in air that can
ignite is defined as the Lower Explosive Limit (LEL). A combustible
gas reading of "XXX" indicates the atmosphere is above 100 %
LEL or 5.00 %vol CH4, and an explosion hazard exists. Move
away from hazardous area immediately.
Do not use the ALTAIR 5X, or ALTAIR 5X IR MultiGas Detectors to
test for combustible or toxic gases in the following atmospheres as
this may result in erroneous readings:
• Oxygen-deficient or oxygen-rich atmospheres
• Reducing atmospheres
• Furnace stacks
• Inert environments (only IR sensors acceptable for use)
• Atmospheres containing combustible airborne mists/dusts.
Do not use the ALTAIR 5X or ALTAIR 5X IR MultiGas Detectors to
test for combustible gases in atmospheres containing vapors from
liquids with a high flash point (above 38 °C, 100°F) as this may
result in erroneously low readings.
Allow sufficient time for unit to display the accurate reading.
Response times vary based on the type of sensor used (see
Section 5.3, "Sensor Performance Specifications"). Allow a
minimum of 1 second per foot
(3 seconds per meter) of sample line for the sample to be drawn
through the sensors.
Sampling lines made from 0.062 inch (1.57 mm) inner diameter
tubing provide fast transport times to the instrument; however, they
must be limited to 50 feet (15 m) in length.
Sampling of reactive toxic gases (Cl 2 , ClO 2 , NH 3 ) must only be
done with the reactive gas sample line and probe kits listed in the
Section 6.2 Accessories table.
All instrument readings and information must be interpreted by
someone trained and qualified in interpreting instrument readings
in relation to the specific environment, industrial practice and
exposure limitations.