DATA RESET Procedure: The "Data reset" procedure is carried out only in
manual mode. Before resetting data, the machine performs a backup of the data
to be replaced.
SYMBOL
Push-mode ROC: (selected to perform the ROC without removing the vehicle's
wheels from the lift or from the floor. Carried out by pushing the vehicle
backwards about 30 and then forwards up to the starting point).
ROC skip: (The working procedure moves on straight to the working windows,
without performing the ROC calculation).
ROC Recall: (Recalls the data from the last ROC procedure performed.
Normally used when the data have to be recovered, without having to repeat the
ROC procedure, after a power failure while a job is in progress).
The window shown in figures 14-15 is displayed when there is a reading or measurement error.
The figure shows the two vehicle axles and a line plus an arrow indicate between which targets
the error is present.
In these cases, the cause of the error must be corrected in order to resume normal operation.
If this is not possible, press F10 to go back to the starting screen and correctly exit the program.
Then call in the Technical Support Service.
If the program is used only as a demo, without using the targets, the program should ignore the
measurement and transmission errors resulting from the absence of targets.
To do this, select the "Demo" option in the Service" window.
To access the service window, press the F8 key from the program starting screen.
In this situation ("Demo" mode), a special icon is displayed in the top right-hand corner of the
heading bar. The values displayed are completely random.
At the end of the demo, remember to repeat the same procedure to return the machine to
working status.
The following keys are active in the main (initial) window (fig. 7):
- F1
displays the on-line "Help".
- F2
exits the alignment program (with password prompt) and return to the Windows desktop.
- F3
(or "Enter") goes to the next screen in the established operation sequence (job record,
vehicle / customer databank, compensation, measurement).
- F4
sets up all the status option settings (set-up).
- F6
recovers the last job done (with icon active).
- F8
opens the utility procedures window.
- F9
skips vehicle selection from the databank ("generic vehicle" mode).
- F10 exits the alignment program and Windows with the correct power-down procedure.
Press the F4 key to display/set up all the aligner options.
The general set-up function (F4 from the starting screen) has been provided because some
users prefer to change all the available options before starting the measurement procedures.
MENU AVAILABLE IN THE ROC STATUS
FUNCTION DESCRIPTION
ERROR WINDOW
MAIN WINDOW
23