Filling The Solution Tank & Dustguard™ Tank - Advance CS7000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A-18 / ENGLISH
FILLING THE SOLUTION TANK
See Figure 6. Fill the solution tank with a maximum of 75 gallons (284 Liters) of cleaning solution. Do not ll the solution tank above 7.5 cm (3
inches) from the bottom of the Solution Fill (4). The solution should be a mixture of water and the proper cleaning chemical for the job. Always
follow the dilution instructions on the chemical container label. NOTE: EcoFlex machines can either be used conventionally with detergent mixed
in the tank or the detergent dispensing system can be used. When using the detergent dispensing do not mix detergent in the tank, plain water
should be used.
CAUTION!
Use only low-foaming, non- ammable liquid detergents intended for machine application. Water temperature should not exceed 130
degrees Fahrenheit (54.4 degrees Celsius).
FILLING THE DUSTGUARD™ SOLUTION TANK
See Figure 6. Fill the solution tank with a maximum of 29 gallons (110 Liters) of water. Do not ll the solution tank above 7.5 cm (3 inches) from
the bottom of the DustGuard Tank Fill (18). Do not mix detergent in the tank, plain water should be used.
FIGURE 6
A-18 - FORM NO. 56041979 - CS7000

Publicité

Table des Matières
loading

Table des Matières