Elixo 500 3S io
2. PRODUCT DESCRIPTION
2.1. Scope of application
The ELIXO 3S motorisation is designed to motorise a sliding gate weighing
up to 500 kg.
To ensure the safety of all equipment and persons, respect the information
given in the table below:
For a gate weigh-
install at the end of the
ing:
0 to 200 kg
Passive rubber block, h58
200 to 500 kg
Passive rubber block, h90
If using a different rubber block to those listed above, ensure that the in-
stallation conforms to current regulations.
2.2. Composition of the standard kit - Fig. 1
Mark
Quantity
Motorisation
1
Elixo 24 V Motor
1
2
Remote control
2
1
Manual release handle assembly
3
2
Handle locking key
4
2
End limit bracket
5
Ground mounting kit
4
Coach screws
6a
12
Nut
6b
8
Washer
6c
1
Drilling template
7
1
Metal plate
8
The composition of the kits may vary.
2.3. Description of the motorisation - Fig. 2
Mark
Upper cover screw
1
Upper cover
2
Cover
3
24 V motor
4
Reduction unit
5
Electro-mechanical end limit unit
6
Pinion
7
Manual release mechanism
8
Control unit
9
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Ref.
gate:
9019613
9019612
Description
Description
Mark
Battery pack (optional, ref. 9016732):
a
2 backup batteries
10
b
Battery holder tray
c
Battery power supply management card
Battery (option, ref. 9001001)
11
Fuse (250 V/5 A) for 230 V lighting output
12
Spare fuse (250 V/5 A)
13
2.4. Description of the interface
3-digit LCD screen
Display of parameters, codes (operation, programming, errors and break-
downs) and memorised data.
Para meter value display:
• fixed = value selected/auto-adjusted
• flashing = value selectable for parameter
Button
Navigate the parameters and codes list:
• short press = scroll through individual parameters
• press and hold = scroll rapidly through parameters
• Launches the auto-programming cycle
• Validates the selection of a parameter
• Validates the value of a parameter
Modifying the value of a setting
• short press = scroll through individual values
• press and hold = scroll rapidly through values
Using forced operating mode
• Press 0.5 sec: Enters and exits the parameter setting
menu
• Press 2 sec: Triggers auto-programming
• Press 7 sec: Deletes auto-programming and parame-
• Interrupts auto-programming
• Press 2 sec: Memorises the remote controls
• Press 7 sec: Clears the remote controls
2.5. General motor space requirements - Fig. 3
Description
Function
ters
EN