LEVELLING
Adjust the floor-mounted feet to level the appliance.
Important
With a height difference between the feet (A and
B) > of 10 mm, the specific ROLL-IN RAMP KIT
must be installed

ELECTRICAL CONNECTION

Caution - warning
The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specified materials.
The appliance is supplied with operating voltage 230V/1N 50 Hz (230V/1N 60 Hz
available on request) (see attached wiring diagrams)
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply
as follows.
1 – If not already present, install an automatic circuit-
breaker (B), close to the appliance, with the following
characteristics.
– Thermal breaker device (to adjust see table on
page 5)
IT
– Differential breaker set at 30 mA
– Class B or C (IEC 898)
GB
2 – Undo the screws and remove the side panel (A).
3 – Connect the automatic circuit-breaker (B) to the
DE
appliance's terminal board (C) and to the electrical
mains supply, in accordance with the electrical sys-
FR
tem diagram provided at the back of the manual and
using a cable with the following characteristics.
ES
– Weight:
than H05RN-F type (designation 245
IEC 57)
– Temperature of use:
Important
When connecting, take care to connect the neu-
tral and earth lines.
4 – Replace the panel and retighten the screws when
the operation is complete.
English
70°C.
B
A
C
- 54 -
B
A
IDM-39619201200.tif