RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment, activate all the safety devices provided
and decide whether staff at work and those in the vicinity should be informed.
In particular, turn off the gas and water supply taps, cut off the electricity supply
using the master switch and prevent access to all devices which might cause
unexpected health and safety hazards if turned on.
Caution - warning
Adjustments must be carried out by authorised, qualified staff, in accordance
with the relevant legal requirements

CHECKING GAS PRESSURE

To carry out this operation, proceed as follows.
1 – Turn off the gas supply tap (A).
2 – Undo the screws to remove the side panel (B).
3 – Unscrew the screw (C).
4 – Connect the pressure gauge (D) to the pressure
test point (E).
5 – Turn the gas supply tap (A) back on.
6 – Switch on the appliance (see page 8) and carry
out a cooking cycle without food at the maximum
temperature.
7 – Check that the pressure gauge reading complies
with the values (see table at back of manual).
8 – Switch off the appliance, turn off the gas supply
tap (A), and disconnect the pressure gauge (D) and
retighten the screw (C).
9 – Replace the panel (B) and retighten the screws
when the operation is complete.

CHECKING THE COMBUSTION EXHAUST GASES

Once the appliance has been connected (see page 54), proceed to analyse the com-
bustion exhaust gases as described:
1 – Acquire an exhaust gas analyser and calibrate the instrument in accordance with
the instructions in the operator's manual supplied with it.
2 – Insert the exhaust gas analyser's measuring pipes into the appliance's exhaust gas
discharge lines.
3 – Switch on the appliance (see page 8).
4 – Access the "Service" menu and activate the "CO/CO2 Measurement" procedure
(see page 10).
5 – Check the CO and CO2 emission values first at minimum power (cold), then at
maximum power, and then at minimum power (hot) again.
6 – Check the values obtained against the data provided in the enclosed table.
7 – Fill in the relative test report (enclosed) and send it to the manufacturer to activate
the Warranty.
Important
The maximum exhaust gas temperature at the outlet is about 400 °C.
English

ADJUSTMENTS

C
E
- 59 -
B
D
A
50
48
46
44
40
38
36
Use and installation manual
8
IDM-39619300900.tif
IT
GB
DE
FR
ES

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fx 202 g3Fx 201 g3pFx 202 g3p

Table des Matières