Fault - Angelo Po FX 201 G3 Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The "cleaning spray" should be used to spray the cleaner onto the inside of the cook-
ing chamber.
6 – Rinse with warm (drinking quality) water and dry the surfaces of the cooking cham-
ber.
7 – Spray on the polishing product and leave it to act for a few minutes.
8 – Rinse with warm (drinking quality) water and dry the surfaces of the cooking cham-
ber.
9 – Screw the screws back in to close the deflector panel (B).
10 – Replace the filter mesh (A).
Caution - warning
On completion of the cleaning procedures, carry out a cooking cycle empty, in
"Steam" mode for 15 min. and for a further 15 min. in "Convection" mode at the
temperature of 150°C before reusing the appliance.
If the oven is to be unused for short periods, leave the cooking chamber open
to prevent condensation from forming.
TROUBLESHOOTING
The appliance has been tested before being put into service.
The information provided below is intended to assist in the identification and correction
of any anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specific technical
knowledge or skill is required, and so they must only be carried out by qualified staff
with recognised experience acquired in the specific sector of operation.

Fault

The appliance does not
switch on
Smell of gas
IT
GB
Cooking cycle does not start
or stops suddenly
DE
FR
The cleaning cycle does not
start or stops suddenly
ES
The burner does not light or
goes out suddenly
Burner does not light or goes
out suddenly with "GAS"
alarm signalled
English
FAULT
Cause
Fuse "blown"
Safety or protection device (safety
thermostat or overload cutout)
tripped
Electronic circuit board damaged
Gas leaks in supply system
Control board electronic circuit board
damaged
Alarm triggered
Control board electronic circuit board
damaged
Alarm triggered
Gas valve faulty
Ignition monitoring fuse "blown"
Air intake in base obstructed
Ignition plug wires disconnected or
damaged
Ignition plugs dirty or damaged
Ignition monitoring device faulty
- 48 -
Remedy
Replace the fuse (see page pag. 61)
Press device reset button
Contact the after-sales service
Check the tightness of the system
Contact the after-sales service
Consult the "Key to Alarms" table
Contact the after-sales service
Consult the "Key to Alarms" table
Replace gas valve
Contact the after-sales service
Clean the air intake
Reconnect or replace the wires
Clean or replace the plugs
Replace the device