Electrical Connection - Angelo Po FX61 E3 Manuel D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 4
Handling and Installation

ELECTRICAL CONNECTION

The appliance must be connected, grounded in
accordance with all local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70, or the Canadian Electrical Code, CSA C22.2.
IMPORTANT _________________________
The connection must be made by authorized,
skilled personnel, in accordance with the
relevant legal requirements, using appropriate
and specifi ed materials. The appliance is
supplied
with
operating
or 240V/3 (available on request only for
model FX61-101-82-122-201-202) or 480V/3
for FX202 (available on request only for model
FX101-82-122) (see wiring diagrams).
WARNING Before performing any service
that
involves
electrical
disconnection and/or exposure to electrical
components, always follow the Electrical
LOCKOUT/TAGOUT Procedure. Disconnect
all circuits. Failure to comply can cause
property damage, injury or death.
Before doing any work, cut
WARNING
off the main electricity supply.
Connect the appliance to the main power supply as
follows.
1. Remove the screws and side panel (A).
2. Connect power input wires to the appliance's
terminal board (C), in accordance with the electrical
system diagram provided at the back of the manual,
using a cable with the following characteristics.
• Wire insulation temperature rating: ≥75°C (167°F).
C
3. Replace side panel (A) and retighten all screws
when the operation is complete.
22 Combination Oven Installation and Operation Manual
voltage
208V/3
connection
or
B
A
IMPORTANT _________________________
Cooking
chamber
rotate
in
a
clockwise
clockwise direction.
TESTING THE APPLIANCE
IMPORTANT _________________________
Before it is put into service, the system
must be tested to check the operating
conditions of every single component and
identify any malfunctions. In this stage, it
is important to check that all health and
safety requirements have been complied
with in full.
To test the system, make the following checks.
1. Turn on the water supply valve and make sure
the connection is watertight.
2. Make sure main (input) voltage is the same as
that of the appliance.
3. Check water pressure and adjust if necessary.
4. Check that the safety device is operating
properly.
5. Perform a cooking cycle without food to ensure
the appliance is operating properly.
After testing, train the user in all skills necessary
to ensure safe operation of the appliance, in
accordance with all legal requirements.
convection
fan
can
and
counter-

Publicité

Chapitres

Table des Matières
loading

Table des Matières