Wiring The Accessories 3; Photoelectric Cells - SOMFY Slidymoove 300 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For your safety, these operations must be carried out with the power supply switched off.
You are advised to perform auto-programming of the gate travel before connecting the accessories
(photoelectric cells, flashing light, etc.)

3.1 Photoelectric cells

It is not possible to connect a second set of photoelectric cells on this drive.
TX
RX
1 2
1 2 3 5
Installation
A er wiring the photoelectric cells:
• switch the motor on again,
• start a gate opening or closing procedure.
The photoelectric cells are recognised by the control electronics once this movement is
complete.
Operation with photoelectric cells
If the cells are blocked when closing the gate, the gate will stop and reopen. If the gate is open
and the cells are blocked, the gate will not close.
In the event of photoelectric cell disconnection
A er disconnection of the photoelectric cells, switch the motor on again then perform the procedure
"Deactivating automatic closing"on page 25.

WIRING THE ACCESSORIES 3

TX
1 2
1 2
or
EN - SLIDYMOOVE 300 installation and operating guide - SOMFY
RX
1 2
19