General Wiring Diagram - SOMFY ELIXO 500 3S io Manuel D'installation

Masquer les pouces Voir aussi pour ELIXO 500 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo 500 3S io

gEnEraL wIrIng dIagraM

230 V
500 W max.
... ...
230 V
50 Hz
1
2
3
4
5
6
L
N
Lamp
230Vac
230Vac
1.5 mm²
terminals
terminal
indications
1
L
2
N
3
L
4
N
5
N
6
L
7
Conductor
8
Braid
9
Contact
10
Shared
11
Contact
12
Shared
13
Contact
14
Contact
15
Shared
16
Contact
17
Contact
18
Shared
19
Contact
20
Shared
21
24 V
22
0 V
23
24 V
24
0 V
25
24 V - 15 W
26
0 V
27
9 V - 24 V
28
0 V
29
EOS O
30
Shared
31
EOS F
32
1
33
2
34
24VAC
35
11
7
8
9
10
11
12
13
Ant.
Aux
Connection
230 V power supply
Transformer primary supply output
230 V lighting output
Aerial
PEDESTRIAN/CLOSING control input
COMPLETE/CLOSING control input
Auxiliary contact output
Safety input 3 - programmable
Safety test output
Safety input 2 - safety edge
Safety input 1 - Cells
Safety device power supply
24 V accessories power supply
24 V - 15 W orange light output
9 V or 24 V low voltage supply input
Motor end limit
Motor
Transformer
TX
RX
14
15
16
17
18
19
20
21
22
-
+
Test
Sec Prog
Sec BP
Sec Cell
24V Cell
0.75 mm²
Comments
Note: Earth connection available on the motor body
Max. power 500 W
Protected by 5A time-delay fuse
PEDESTRIAN/OPENING cycle programmable
COMPLETE/CLOSING cycle programmable
24 V, 1.2 A outage
Safety Extra Low Voltage (SELV)
Only compatible with a dry contact safety edge
BUS compatible (see parameter table)
Used to connect RX cell
Permanent if autotest not selected, controlled if autotest selected
1.2 A max for all accessories on all outputs
Compatible batteries 9.6V and 24V
At 9 V, degraded operation
At 24 V, normal operation
24 Vdc
23
24
25
26
-
27
28
29
30
31
32
-
+
+
+
-
24V dc
Flash
Batt.
EOS O
EOS F
0.75 mm²
Copyright © 2015 Somfy SAS. All rights reserved.
34
35
33
M1
Motor
24Vac
1.5 mm²

Publicité

Table des Matières
loading

Table des Matières