Elixo 500 230V RTS/Elixo 800 230V RTS
DIP -
DIP -
DIP -
Setting
SW 7
SW 8
SW 9
Semi-automatic
OFF
ON
OFF
- pressing the button on the remote control while the
gate is opening will stop the gate,
- pressing a button on the remote control during closing
causes it to reopen.
Automatic
OFF
ON
ON
In automatic mode, the final position of the gate will
always be the closed position.
Operation in automatic closing mode is only authorised
if the photoelectric cells are fitted.
- the gate closes automatically after the time delay
programmed with the TIME potentiometer,
- pressing a button on the remote control during
opening has no effect,
- pressing a button on the remote control during
closing causes it to reopen,
- pressing a button on the remote control during the
closing time delay restarts the time delay (the gate will
close when the new time delay has elapsed).
If there is an obstacle in the cells' detection zone, the
gate will not close. It will close once the obstacle is
removed.
Automatic + cell blocking
ON
OFF
OFF
In automatic mode, the final position of the gate will
always be the closed position.
Operation in automatic closing mode is only authorised
if the photoelectric cells are fitted.
After the gate is opened, movement in front of the
cells (if active cell input during closing is activated)
will close the gate after a short time delay (fixed at
2 seconds).
If there is no movement in front of the cells, the
gate will close automatically after the timed close
programmed in with the TIME potentiometer.
If there is an obstacle in the cells' detection zone, the
gate will not close. It will close once the obstacle is
removed.
Deadman's wired control
ON
ON
ON
The gate can only be controlled by continuous action
on a wired control: opening on OPENING control input,
closing on CLOSURE control input,
The pedestrian and radio controls are inactive.
There is no slowdown zone when the deadman's
wired control is operating,
This operating mode can be activated without
programming.
7.7 Safety edge autotest - Dipswitch 10
DIP - SW 10
Setting
OFF
Without autotest
ON
With autotest
7.8 Orange light warning - Dipswitch 11
DIP - SW 11
Setting
OFF
Without warning
ON
With 2 s warning prior to movement
7.9 Cell autotest when closing - Dipswitch 12
DIP - SW 12
Setting
OFF
Without autotest
ON
With autotest: the autotest is only available for the cell
connected to the cell active during closing input.
7.10 Setting the timed close - Fig. 29
Set the timed close (up to 120  s delay) with the TIME potentiometer if the
"Sequential + automatic timed close", "Automatic" or "Automatic + cell blocking"
operating mode is selected:
- Turn the potentiometer to the right to increase the time delay.
- Turn the potentiometer to the left to decrease the time delay.
Copyright © 2015 Somfy SAS. All rights reserved.

8 - PROGRAMMING THE REMOTE CONTROLS

8.1 Memorising the 2- or 4-button remote control for
pedestrian opening - Fig. 30
[1]. Press and hold (2 s) the PROG button (7, Fig. 3).
The red indicator will come on permanently.
[2]. Press the PROG button a second time.
The red indicator light flashes once slowly.
[3]. Press the button of the remote control that will open the gate for pedestrians.
The red indicator light flashes; the remote control has been memorised.
In pedestrian opening mode, the gate operates for 7 seconds.
8.2 Memorising the 2- or 4-button remote control to
control the auxiliary output - Fig. 31
[1]. Press and hold (2 s) the PROG button (7, Fig. 3).
The red indicator will come on permanently.
[2]. Press the PROG button a second time.
The red indicator light flashes once slowly for 0.5 seconds.
[3]. Press the PROG button a third time.
The red indicator light flashes once very slowly for 2 seconds.
[4]. Press the button on the remote control to control the auxiliary output.
The red indicator light flashes; the remote control has been memorised.
9 - CLEARING THE REMOTE CONTROLS AND
ALL SETTINGS
9.1 Clearing the memorised remote controls - Fig 32
Causes all memorised remote controls to be cleared.
9.2 Clearing the programming - Fig. 33
Clears the programming: offset between the gate leaves, slowdown zone at end
of travel.
10 - TROUBLESHOOTING THE SAFETY EDGE
Troubleshooting must be carried out with the power off.
The safety edge must be reconnected following troubleshooting.
Disconnect the safety edge and create a bridge between terminals 14 and 15 of
the motor electronics.
The motorisation is operating with no safety device.
DANGER