Prerequisites for installation
Stop blocks on the ground
The gate travel must be defined by end stops firmly fixed in the ground.
Opening end stop
Positioning the motor
Electrical pre-equipment
Cables required
• Power supply: 3 x 1.5 mm² cable or
3 x 2.5 mm² for outdoor use
(type H07RN-F minimum)
• Linking of cells: 2 x 0.75 mm² cable
• Other accessories: see page 6
Cable feed
• Underground cables must be equipped with a
protective sheath with a sufficient diameter to
contain all the cables.
• Fit a 230 V electrical input as close as possible
to the motor.
Caps to be drilled
if necessary to
accommodate
additional cables
Closing end stop
Provision must be made for the supply cable
to be fed through according to the electrical
standards in force in the country of use.
If a cable conduit cannot be made, use a cable
grommet which will withstand the passage of
vehicles (ref. 2400484).
Gate
Feed for 230V power
supply cables
and the main accessories
EN - SLIDYMOOVE 300 installation and operating guide - SOMFY
Concrete base