TECHNICAL DATA
Power source:
Mains voltage
(50Hz-60Hz)
±15%
Fuse
Mains current, effective
Mains current, max.
Power, (100%)
Power, max
Open circuit power
Efficiency
Power factor
Current range
Duty cycle 100%
at 20°C
Duty cycle
60%
at 20°C
Duty cycle 100%
at 40°C
Duty cycle
60%
at 40°C
Duty cycle
max.
at 40°C
Open circuit voltage
1
Sphere of application
2
Protection class
Standards
Dimensions (hxwxl)
Weight
Wire feed speed
S
1
This machine meets the demand made for machines which are to operate
in areas with increased hazard of electric chocks
2
Equipment marked IP23 is designed for indoor and outdoor applications
OMEGA 270 MINI
3x400V
10A
6.8A
13.2A
4.7kVA
9.1kVA
20W
0.88
0.93
15-270A
210A
230A
160A
180A
22%
52V
S
IP 23
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
29x22x57 cm
19 kg
18 m/min
19
MAINTENANCE
The machine requires periodical maintenance and
cleaning in order to avoid malfunction and cancellation
of the guarantee.
WARNING !
Only trained and qualified staff members can carry
out maintenance and cleaning. The machine must
be disconnected from the mains supply (pull out
the mains plug!). Thereafter, wait around
5 minutes before maintenance and repairing, as all
capacitors need to be discharged due to risk of
shock.
Wire cabinet
-
Regularly, clean the wire cabinet with compressed
air and check if the grooves and teeth on the wire
drive rolls are worn out.
Power source
Clean the fan blades and the components in the
-
cooling pipe with clean, dry, compressed air as
required.
A trained and qualified staff member must carry out
-
inspection and cleaning at least once a year.