MAINTENANCE
Lack of maintenance can lead to reduced reliability
and repeal of the guarantee.
Power source
With regular intervals dust should be blown out of the
power source with clean, dry compressed air. Choked
or blocked air intake and outlet may result in over-
heating. The power source should be checked and
cleaned at least once a year by trained service staff.
Water module
Waterlevel should be checked regularly. To ensure
reliable operation, always use MIGATRONIC coolant.
If the level of coolant in the tank falls so low that the
machine is disconnected (error information in the
control panel of the current source), then extra coolant
should be added, using the filling nozzle. Coolant
needs yearly renewal.
TECHNICAL DATA
We reserve the right to changes
Power source
Mains voltage
Fuse
No load consumption
Adaptor consumption
Efficiency
Cos.phi
Open circuit voltage
100% duty cycle
60% duty cycle
Current range DC
Voltage adjustment
Inductance positions
Insulation class
1
Protection class
Sphere of application
2
Norm
Cooling system
Dim. lxbxh
Total weight STB
1
Equipment marked IP23 is designed for indoor and outdoor applications
S
2
The machine meets the standards which are demanded of machines
working in areas where there is an increased risk of electric shock
15
KMX 550
400 V
35 A
100 VA
24 kVA
0.85
0.96
15 - 60 V
425 A / 35.25 V
525 A / 41.50 V
40 - 550 A
infinitely variable
4
H
IP23
S
EN/IEC60974-1
EN/IEC60974-10 (Class A)
3 L
94x51x143 cm
229 kg