TECHNICAL DATA
Power source:
Mains voltage (50Hz-60Hz)
Fuse
Power, max.
Efficiency
Current range TIG
Current range MMA
Permitted load:
100% (40° ambient temp.)
60%
(40° ambient temp.)
40%
(40° ambient temp.)
Open circuit voltage
Electrode diameter
Slope down
Gas post-flow
TIG-ignition
1
Application class
2
Protection class
Standards
Dimensions (LxWxH)
Weight
S
1
The machine meets the standards which are
demanded of machines working in areas where
there is an increased risk of electric shock
2
Equipment marked IP23 is designed for indoor
and outdoor applications
The machine requires periodical maintenance
DELTA
200 DC HP
and cleaning in order to avoid malfunction and
1x230 V ±15%
cancellation of the guarantee.
25 A
WARNING !
8.6 kVA
Only trained and qualified staff members
0.89
can carry out maintenance and cleaning.
10-200 A
The machine must be disconnected from
10-180 A
the mains supply (pull out the mains
MMA
TIG
plug!). Thereafter, wait around 5 minutes
125 A
140 A
before maintenance and repairing, as all
capacitors need to be discharged due to
150 A
160 A
risk of shock.
180
200 A
60 V
Power source
1.6 – 3.25 mm
-
Clean the fan blades and the components
0 – 10 sec.
in the cooling pipe with clean, dry,
0 – 30 sec.
compressed air as required.
HF/LIFTIG
-
A trained and qualified staff member must
S
carry out inspection and cleaning at least
once a year.
IP 23
EN/IEC60974-1
EN/IEC60974-3
EN/IEC60974-10
40x18x25.5 cm
9.8 kg
19
MAINTENANCE