13. Technical data
Operating voltage...................... 12 V/DC nominal, 11 - 16 V/DC
Operating current...................... 60 mA (standby), max. 80 mA
Protection type .......................... IP55
Compatible access card .......... type EM-01, type EM-02
Scannable card frequency ...... 125 kHz
Available memory slots ............ Max. 500, 5 memory groups with 100 memory slots each
Door lock pulse, selectable
for fail-safe or fail-secure........ Max. 16 V/DC, 3 A
Doorbell relay ............................ N. O. (normal open) potential-free contact,
Tamper switch ........................... N. C. (normal close) potential-free contact,
Doorbell output .......................... Relay contact for triggering an optional doorbell
Cable cross-section.................. Max. 0.326 mm
Operating conditions ................ -20 to +70 ºC, 5 – 95 % RH (non-condensing)
Storage conditions.................... -20 to +70 ºC, 5 – 95 % RH (non-condensing)
Number of add. devices ........... Max. 3 (up to three additional card readers can be
Dimensions (W x H x D)............ 60 x 119 x 23 mm
Weight ......................................... 87 g
Access cards type EM-01, item no.: 1308120
max. 24 V/DC, 1 A
max. 16 V/DC, 50 mA
2
ordered as an accessory)
61