14. Technical Data
Operating voltage............................... 12 - 24 V (AC or DC)
Max. power consumption ................. ca. 160 mA
Stromaufnahme Standby .................. ca. 15 mA
Current consumption ........................ approx. 15 mA standby:
Single user codes: ............................. (4numbered) 10.000 combinations
...............................................................
Multi-user codes: ............................... (4 - 8 numbers) 10 Mio combinations
...............................................................
...............................................................
Bell contact ......................................... max. 30 V/DC, 1 A, current free
Output 1................................................ max. 30 V/DC, 5 A, current free
Output 2................................................ max. 30 V/DC, 1 A, current free
Output 3................................................ max. 24 V/DC, 100 mA
NPN outputs........................................ max. 24 V/DC, 100 mA
Key press time .................................... max. 10 seconds between each key press
keypad illumination ............................ Standby: dimmed
...............................................................
Working temperature ........................ -40 to +85 °C
Protection type ................................... IP 54
Dimensions ......................................... 117 x 117 x 28 mm (LxWxD)
Weight .................................................. Approx. 180 g
68
1 master code; 3 user codes
1 master code; 100 user codes for output 1
each 10 user codes for output 2 + 3
keypress: 10s nright/3s by bell button