Programming - Renkforce AR-2808 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

d) Programming
During programming, the system must be operational and in normal operating mode. A
master card must be created beforehand.
Using the master card for 5 program groups
Program group 1
Registering access cards. The master card will be scanned 1x.
Program group 2
Erasing access cards. The master card will be scanned 2x.
Program group 3
Setting output mode for the door lock. The master card will be scanned 3x.
Program group 4
Setting the access system's safety activation. The master card will be scanned 4x.
Program group 5
Creating/erasing super access cards. The master card will be scanned 5x.
Scanning the master card
• Set the system for programming with the master card. The master card will be
scanned from 1 to 5 times for the different program groups. Each scan of the master
card must be within 2 seconds.
• Scan the master card 1x to exit programming mode.
The card reader remains in programming mode until it is exited using the
master card.
Acoustic signals in programming mode and during operation
1 beep - Jump to next field when selecting a program group.
2 beeps - Action successful.
5 beeps - Action not successful.
1 long beep - A previously registered card is rejected in programming mode.
46

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1308117

Table des Matières