3.2.2 Control Terminal
3.2.4 Technical Specifications
HWT 400–M
Power Supply Specifications
Voltage
Frequency
Power overall
Power Heating Element
Power Facing Tool
Power Hydraulic Unit
Power Other Devices
Welding Operation Specifications
Heating Element Temperature
Facing Tool Speed
Pressure Application
Section of Hydraulique Cylinder
Ambient Temperature (Operation)
Ambient Temperature (Storage)
Operating Range
straight pipe, segmented bends
tees, Y branch-offs, crosspieces
Dimensions and Weight
Dimensions (W x D x H)
Machine only
Space Needed in
Working Position
Weight w/ Steel Clamping Assemblies
Weight w/ Cast-alum. Clamping Ass.
Maximum Stroke of the Carriages
The power supply connection is designed as a 3-phase plus
earth ground plus neutral connection. The power supply
connection should be rated at 16 amps and should be wired
Important
with an automatic safety cut-out of 16 amps medium-slow
blow. The conductor section of the power supply connection
should be minimum 2.5 sq. mm.
For the connection to mains power an approved CEE plug
and outlet have to be used and wired according to the speci-
Important
Version January 2020
3 Ph/PE/N, 400 V AC ± 10%
50/60 Hz
9 kW
5 kW
1.85 kW
1.50 kW
0.65 kW
max. 290°C
25.0 rpm
max. 120 bar
7.069 cm²
+0°C to +60°C
–10°C to +70°C
90 - 400 mm
90 - 315 mm
approx. 1100 x 1500 x 1600 mm
approx. 1200 x 1700 x 1600 mm
(refer to instructions on installation site, Sect. 2.6)
557 kg
642 kg
approx. 500 mm
HÜRNER HWT 400–M User's Manual
Maximum Pressure Regulator
Carriage Mover Lever
Pressure Gauge
Manual Pressure Release Regulator
Screen Displaying the Temperature and
Two Pushbuttons for Decreasing and
Increasing the Nominal Temperature
Full Pressure Release Valve
9