EN
Parameter modification options:
•
temperature set-point for the sauna (from 40 °C
to 110 °C) in increments of 5 °C;
•
sauna function duration (h:mm format).
h: values in the interval 0÷6 hours. 1-hour
increment setting;
mm: values in the lower interval 0÷55. 5-min.
increment setting.
When one of the three parameters is selected, it
may be modified within allowed values, through the
keys
and
You exit the INACTIVE SAUNA screen when:
•
keys are not pressed for 5"; any modification,
even partial, are not saved and keypad en-
ters the "READY" or "FUNC.ON" state;
•
key
pressing entailing:
- saving of visualized parameters (duration and
temperature);
- prompt activation of function; the SAUNA key
becomes steady bright in LIGHT BLUE (see
sauna mode active). The keypad passes to on-
going sauna screen visualization:
- MAN/AUTO;
- Current temperature in sauna;
- Sauna functioning time counter (counter de-
creasing during functioning).
SAUNA SETTING IN AUTOMATIC MODE
In this state, it is possible to set the sauna function
activation at a pre-set time and duration. The follow-
ing actions must be carried out:
•
set the temperature set-point for the sauna
(from 40 °C to 110 °C) in increments of 5 °C;;
•
set the function activation time (format hh:mm
with increments of 5 minutes);
•
set the function switching off time (format hh:mm
with increments of 5 minutes).
The max. duration must be restricted to 6 hours.
After having selected the AUTO mode, when press-
ing the key
goes on; the editable parameters are indicated in
negative.
28
.
, the parameter setting screen
5sec.