Teuco ARJA Manuel De L'utilisateur page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

After having selected the AUTO mode, when press-
ing the key
, the parameter setting screen is
entered; the editable parameters are indicated in
negative.
The parameter values can be modified through keys
and
; you move from a parameter to
another, and from hour to minute, through the keys
and
.
The first screen automatically proposes the
start and stop times.
start time: hour and minutes rounded up
to "5 following minutes".
Ex. current time 10:04  start time 10:05;
stop time: 6 hours after start.
Ex. start 12:15, stop 18:15.
If the start time is set earlier than the current
one, it is deemed to be programmed for next
day.
If the user sets duration above 6 hours, the
system automatically corrects the stop time to
make it fall within the allowed range.
Every time a key is pressed in the function, a
tout of 5" is initialized.
The max. start time is the current time plus
23h:55'.
The max. stop time is the start time plus 6
hours (max. function duration).
Pressing the
key briefly saves the parameters
set, the
key blinks in WHITE 1"ON/1"OFF (to
indicate the programming is active), and, while wait-
ing for the time to elapse, inhibit further modifica-
tions.
Wait the tout end to exit the function.
When tout elapses:
You return to "FUNCT. ON" or "READY" mode
depending on whether the chromotherapy func-
tion is active or not.
EN
23

Publicité

Table des Matières
loading

Table des Matières