MESSAGES
MESSAGES
The upper left hand side of the display shows the various message types concerning the normal operating
conditions of sauna, malfunctioning and hazardous situations.
VARIOUS SYSTEM MESSAGES
Please note: All messages listed hereunder require the intervention of the Teuco Technical
Assistance.
General remarks in case one or more alarms:
•
all ongoing functions are cancelled;
•
all LEDs go off;
•
on LCD display a screen with all detected alarms (max. 10) is shown at high intensity.
Alarm code
visualized
SAUNA, CHROMOTER-
E1_1
none
E2_1
E2_2
E2_3
E3
E4
•
After 30", the backlight returns to low intensity;
•
The keypad remains locked in this state until reset;
•
Pressing the key
on the detected alarm, are shown.
The alarm relay on the power board is activated when any alarm occurs.
The most common alarms are:
•
Thermal fuse alarm;
•
Temperature probe alarm.
Function
APY
Communication alarm with
CHROMOTERAPY
SAUNA
Temperature 1 probe alarm
SAUNA
Temperature 2 probe alarm
SAUNA
SAUNA
SAUNA
, a "toggle" screen is activated, where the "inner alarm codes", giving more details
Description
Failure to communicate between
POWER communication
alarm
between keypad and DLC. Com-
DLC
Thermal fuse alarm
(work)
ror, cut off power supply and turn
(TbD)
Keypad EEPROM fault
"Emergency stop" alarm
Possible causes
keypad and power.
Communication timeout (5").
In reset, failure to communicate
munication timeout (5").
Temperature >= 140°C.
Temperature out of range
(1÷125°C). In case of replace-
ment of the probe, to cancel er-
it on again.
Temperature out of range
(1÷125°C).
Error R/W.
Contact closing.
EN