Ecolab Versatronic Manuel D'utilisation page 416

Masquer les pouces Voir aussi pour Versatronic:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Device menu
Configuration item
KT X Saturday biocide 1 T1 Hours / minutes / seconds
KT X Saturday biocide 1 T2 Hours / minutes / seconds
KT X Sa biocide 1 T3
(only with C2 and C3) *
KT X Sa biocide 1 T4
(only with C2 and C3) *
KT X Sa biocide 2 T1
(only with C1) *
KT X Sa biocide 2 T2
(only with C1) *
* = see
Ä Chapter 5.3 'Material code' on page 40
Configuration point Selection / option
KT X desalination
monitoring y / n
KT X time desalination
monitoring
KT X signal monitoring
y / n
KT X time Signal
monitor.
KT Cal.timer X y / n
KT X Calibr.interv.
KT X Source Temp.
Ch. X Temp.connection
type
417102269 Rev. 2-08.2020
Selection / option
(hh:mm:ss) Range: 0-23: 0-59:
0-59
(hh:mm:ss) Range: 0-23: 0-59:
0-59
Hours / minutes / seconds
(hh:mm:ss) Range: 0-23: 0-59:
0-59
Hours / minutes / seconds
(hh:mm:ss) Range: 0-23: 0-59:
0-59
Hours / minutes / seconds
(hh:mm:ss) Range: 0-23: 0-59:
0-59
Hours / minutes / seconds
(hh:mm:ss) Range: 0-23: 0-59:
0-59
Inactive active
Number field
Range: - 999 to 999 s
Inactive active
Number field
Range: - 999 to 999 s
Inactive active
0-9999 days
*IN4 temperature input 1
* IN5 temperature input 2
...
IN11 Universal input. 2
uncomp.
* IN11 Universal input. 2
comp.
IN12 Universal input. 3
uncomp.
* IN12 Universal input. 3
comp.
* = Please select only the highlighted points
2-wires
3-wires
144
Explanation
Biocide dosage 1
Time 1
Saturday
Biocide dosage 1
Time 2
Saturday
Biocide dosage 1
Time 3
Saturday
Biocide dosage 1
Time 4
Saturday
Biocide dosage 2
Time 1
Saturday
Biocide dosage 2
Time 2
Saturday
Explanation
Enable desalination monitoring
(If the desalination process is
not completed a set time after
desalination starts, the display
shows "Desalination alert".)
Set the time for desalination
monitoring
Enable signal monitoring
(If a biocide dosing is pending
but the enable signal is
missing, there is a set waiting
to see if the signal comes in. If
no enable signal is given after
the time period lapses, a
"Release signal alert"
appears.)
Setting the time for signal
monitoring
Enable calibration timer
Set the calibration interval
The calibration interval is the
time after which a calibration
reminder is displayed (see
Ä Chapter 9.1.4 'Display
elements' on page 85). After
performing a calibration, the
calibration reminder
disappears.
Determining the source for the
temperature display and for
the temperature compensation
of the respective channel.
Select this option to use the
temperature signal of another
channel for the display and
temperature compensation of
this channel.
Temperature sensor
connection type
Default
00:00:00
00:00:00
00:00:00
00:00:00
00:00:00
00:00:00
Default
Inactive
0 sec
Inactive
0 sec
Inactive
10 days
Channel 1: IN4
Channel 2: IN5
Channel 3: IN11
comp.
Channel 4: IN12
comp.
3-wires

Publicité

Table des Matières
loading

Table des Matières