7.2.4
Cable cross sections, basic and power supply
The terminals of the base and power supply are spring-loaded terminals.
Wire sleeve
No ferrules
Power adapter
Base
Ferrule without collar
Power adapter
Base
Ferrules with collars
Power adapter
Base
Rigid
Power adapter
Base
7.2.5
Conductor cross-sections option board
The terminals of the option boards are plug-in screw.
Option board for
Universal inputs
Analogue outputs
Binary inputs
Binary outputs PhotoMOS® (1)
Logical outputs
Power supply output
Analyseeing. pH / redox / NH
Analysis inputs CR (
Analysis inputs Ci (
Relay binary outputs
Triac binary outputs
(
1
) PhotoMOS® is a registered trademark of Panasonic.
2
(
) Analysis inputs CR = analysis inputs for conductive conductivity
(
3
) Analysis inputs CR = analysis inputs for conductivity inductively
Performance section
Min.
0.2 mm²
0.2 mm²
Min.
0.25 mm²
0.25 mm²
Min.
0.25 mm²
0.25 mm²
Min.
0.2 mm²
0.2 mm²
Wire sleeve
No ferrules
Ferrules with
collars
Ferrule without
collar
Rigid
No ferrules
2
Ferrules with
)
collars
3
)
Ferrule without
collar
Rigid
Max.
1 mm²
1 mm²
Max.
0.75 mm²
0.75 mm²
Max.
0.75 mm²
0.75 mm²
Max.
1.5 mm²
1.5 mm²
Performance section
Min.
Max.
0.14 mm²
1.5 mm²
0.25 mm²
0.5 mm²
0.25 mm²
1.5 mm²
0.14 mm²
1.5 mm²
0.2 mm²
2.5 mm²
0.25 mm²
1.5 mm²
0.25 mm²
2.5 mm²
0.2 mm²
2.5 mm²
53
Electrical connection
Stripping length
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
Stripping
length
7 mm
7 mm
7 mm
7 mm
7 mm
7 mm
7 mm
7 mm