Extending Valve Positions - Aventics CD01-PI Notice D'instruction

Système de distributeurs taille 01, 26 mm, plug-in
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 99
90
AVENTICS | CD01-PI | R412012449–BAL–001–AD
Extension and Conversion
Fig. 14: Mounting base plates
10.5.3

Extending valve positions

You have to unscrew the VS at the respective spot to add valve
positions, insert a new base plate and then screw both VS parts
back together again.
1. Release the two screws (59) at the place where you want to
insert a base plate.
2. Remove the left part of the VS.
3. Mount the new base plate on the base plate of the right part
of the VS so that an electrical connection is established via
the cascade plug-in system. Ensure at the same time that
the sealing is firmly seated.
The encoded pin engages with the respective hole (60).
4. Insert the two M5 screws (59) in the base plate.
5. Tighten both screws equally.
Tightening torque: 5 Nm
6. Repeat step 3–5 for the left part of the VS.