AVENTICS | CD01-PI | R412012449–BAL–001–AD
Extension and Conversion
Fig. 15: Insert the pressure zone separators
4. Mount the left part of the VS on the base plate of the right
part of the VS so that an electrical connection is established
via the cascade plug-in system. Ensure at the same time
that the seal (62) is firmly seated.
The encoded pin (63) engages with the respective hole.
5. Insert the two M5 screws into the base plate.
6. Tighten both screws equally.
Tightening torque: 5 Nm