Saphir compact air conditioning system
Table of contents

Symbols used ........................................................................ 7

Technical data ..................................................................... 7

Intended use .......................................................................... 8
Regulations ............................................................................ 8
Selecting a location ........................................................... 8
Installation dimensions .......................................................... 8
Installing the air conditioning system ............................ 9
Cold air distribution ............................................................... 9
Circulated air return ............................................................. 10
Installing the IR receiver ................................................. 10
receiver .............................................................................. 10
IR remote control mounting ................................................ 10
Symbols used
The device must only be installed and repaired by an
expert.
Symbol indicates a possible hazard.
Note containing information and tips.
Technical data
Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir compact, comfort air conditioning system
Dimensions (L x W x H)
560 x 400 x 290 mm
Weight
20 kg
Power supply
230 V - 240 V ~, 50 Hz
Maximum cooling power
1800 W
Starting current
15 A (150 ms)
Power consumption
2.8 A / 35 °C
Protection class:
IP X5 (when installed)
Volume flow (cold air)
max. 310 m³/h
Refrigerant
R 407C / 0.39 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global warming potential (GWP)
1774
CO2 equivalent
691.9 kg
Maximum incline of vehicle during
operation
8 %
Usage limits
+16 °C to +40 °C.
- An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C.
- An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
- A temperature switch prevents excessive current and tem-
perature at the compressor.
E24 10R-040991
Right reserved to make technical changes!
EN
7