> Checking the mechanical setting of the door
After auto-programming, perform manual back release of the drive to check that the door has not been closed too strongly.
• Back release occurs normally,
• Back release is impossible
(see page 15 - case no.1).
WARNING
• At the end of installation, it is essential to check that the obstacle detection complies with appendix A
of
.
• Failure to follow this instruction may result in serious injury, e.g. due to crushing by the gate.
The programming procedures below must only be followed if you want to change the default value
of the parameters.
To save the parameters selected, press button A successively until the LEDs go out.
By default, the parameters are automatically saved after a 2-minute time-out after which the electronics switch to standby.
> Choice of obstacle detection sensitivity
1
• Press button A" repeatedly until
"A
once. "Obstacle detection sensitivity" mode is
activated.
• The number of times "N" that indicator light "B
the parameter, see table below).
Indicator light A
Indicator light B
WARNING
If this parameter is changed, it is essential to check that the obstacle detection complies with appendix A of standard EN 12
453. Failure to follow this instruction may result in serious injury, e.g. due to crushing by the gate.
x 1
Obstacle detection sensitivity
very low sensitivity
low sensitivity
Standard (default value)
high sensitivity
Programming
2
N
x 1
• Press button "B" to change the value of
the parameter.
Press the button A
3
exit the settings menu.
EN - GDK installation and operating guide - SOMFY