Connection Assignment; Connecting To Extractor System - Hettich BlueMax Mini Modular Instructions De Service

Masquer les pouces Voir aussi pour BlueMax Mini Modular:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Start-up / trial run

Connection assignment

No.
Designation
1
Connection 1
2
Connection 2
3
Connection valve for foot pedal
4
Connection 4
Remove dummy plug
from distributor and connect
5
compressed-air hose to connector on foot pedal.
Note:
Always carry out a function test after
completing this work.
Warning!
The compressed-air hoses must not be damaged
or kinked.
Be sure to follow the assembly instructions in the
appendix to this operating manual.

9. Connecting to extractor system

Connect the machine to an extractor system. It is
compulsory to use a flexible, fire-retardant hose for
connection to an extractor system.
Fit the extractor system's extraction hose to suction
connector
and secure this in place with a hose
1
clamp.
The extractor system must have an airflow rate
of at least 20 m/s.
Extraction hose diameter: ø 80 mm. Route extraction
hose so as not to exert strain on the suction
connector!