Troubleshooting
FAULT
The unit will not switch on
The forward speed is not correct
Tonnage counter reading incorrect
Calibration test
Shutters open to maximum then to minimum
The unit switches on correctly, but the actuators do
not move
Area counter reading incorrect
Flow rate
SOLUTIONS
Check - unit / power cable connections
- power cable fuses
Check - connection on unit
- magnet / sensor distance
- correct rotation of the magnet
- sensor wire continuity (resistance 100Ω ± 10)
- 100m coefficient
Check - connection / machine
- working width
- forward speed
- fertiliser coefficient
- shutter opening and closing
Check - calibration factor (T)
Repeat the calibration test
Check - tractor forward speed coefficient.
- spreading width (24.00 beware of the decimal point)
Check - the fuses
Check - connection / machine
- working width
- forward speed
Check - programmed flow rate
- fertiliser coefficient
- PTO speed 540 rpm
- spreading width
- tractor forward speed
- shutter opening/closing
- actuator travel
- tramlining
GB
4
83