System Parameter Setting

The power switch is located on the back of the display. The display returns to self-test after
power-up, which includes checking whether the LED display is normal and whether the system
resolution and model settings match.
The self-monitoring state continues until the display changes to the normal display state.
If you press
once during the self-test process, the display changes to the state for setting the
system parameters.
There you can make the following system parameter settings:
1. Selection of encoder type (linear or rotary encoder)
2. Set the resolution (fixed resolution selection: 0.1 um, 0.2 um, 0.5 m, 1 um, 2 um), 2.5 um,
5 um and 10 um).
3. Setting the counting direction (0: positive direction, 1: negative direction)
4. Setting the compensation mode (linear or non-linear compensation)
5. Set the rotary encoder parameter
6. Select display type

25.4.1 Encoder Type Selection

L
stands for a linear displacement transducer that matches the axis: R
INER
rotary encoder that matches the axis.
Press
to alter the encoder type of X axis.
Press
to alter the encoder type of Y axis.
Press
to alter the encoder type of Z axis.
Press
to enter step 2 and press

25.4.2 Resolution Setting

For a linear encoder, set the resolution as follows:
1. Select resolution (0.1 um, 0.2 um, 0.5 m, 1 um, 2 um, 2.5 um, 5 um, 10 um)
2. Press
to alter the resolution of X axis, press
press
, to alter the resolution of Z axis.
For encoders, enter the system parameter setting and select encoders. The information screen
shows the L\R type and the X axis shows Rotary. Then press
the encoder when the information screen displays XYZ-Res.
The resolution varies depending on the encoder type, so you must enter the resolution for the
corresponding encoder type.
When entering the resolution, a negative value gives the counting mode in
degrees/minutes/seconds (DMS) and a positive value gives the counting mode in degrees (D).
The display supports a maximum resolution of 99999.
Example: Set the encoder resolution to 1000 P/R:
HOLZMANN MASCHINEN GmbH
DIGITAL POSITION INDICATOR (DITRON DL50 SERIES)
to save and exit parameter setting.