General; A.1 Introduction; A.1.1 About This Guide; A.1.2 Unpacking - AOIP THERMYS 150 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A.
G
ENERAL
A.1
Introduction
The THERMYS 150 is a very-high-precision portable thermometer, capable of simultaneous measurements on two separate channels (differential measurements
or comparative measurements). It is intended more particularly for calibration and maintenance. It can measure physical and electrical quantities either on site
or in the laboratory.
It can perform all the following functions:
Measure temperatures by thermocouples, resistive probes, thermistors over 2 insulated channels.
Recording of measurements and their display as a table or trend curve.
Simulate temperatures using thermocouples, resistive probes and thermistors on 1 isolated channel.
Calibration and generation of the calibration report.
Possibility of using calibrated sensors with memorisation of the calibration factors
The THERMYS 150 has many associated functions that extend its range of application:
Relative measurement.
Results displayed based on a linear or other conversion law.
Synthesis of curves.
Compatibility with 21CFR Part 11 standard for electronic records
A number of improvements have provided it with:
Rapid access to all its functions.
Intuitive user interface.
Bluetooth® Interface
Advanced on-line help system.
Multi-functions keys defined step-by-step on the display.
Connections which can be made with 4 mm safety plugs.
Protection against overloads.
Powered by a rechargeable battery with rapid internal charger.
The unit is enclosed in an ABS case with rubber sheath.
A.1.1
About this guide
This user guide consists of four parts: A, B, C and D.
Part A contains general information and a description of the hardware and software of the unit. It also contains a paragraph on safety and user precautions.
Part B contains brief handling information and a description of the various modes of operation.
Part C contains a description of the advanced functions.
Part D contains the technical specifications of the THERMYS 150.
A.1.2
Unpacking
All THERMYS 150 units are mechanically and electrically checked before delivery. The necessary precautions have been taken to ensure that they reach the user
undamaged.
However, it is a good idea to make a brief check for any damage that may have occurred during transportation. If this is the case, make an immediate claim
against the carrier.
The following accessories are standard:
This user guide
A mains unit for charging the battery pack
4 measurement cables and 4 crocodile clips
Mounting strap
A.1.3
Returning
If the unit is to be returned, it is preferable to use the original packaging and state as clearly as possible, in a note attached to the unit, the reasons for its
return.
Warning
The packaging supplied with the calibrator can withstand a maximum pressure of 20 bar at 21°C (290 psi at 70°F). Subjecting the package to a
higher pressure risks damaging the unit.
AOIP SAS
Rue Dupont Gravé
F-14600 Honfleur
From France :
01.69.02.89.30
From your country :
+33(1) 69.02.89.50
Fax : +33(1) 69 02 89 60
Email : sav@aoip.com
A
Introduction
59/107

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour AOIP THERMYS 150

Table des Matières