6.5
EasyClean free Auto Mix version
Carry out disposal
Start pumping out
Connect the suction hose of the disposal vehicle to the
Storz-B coupling.
Start the pumping process at the disposal vehicle.
Partial emptying
Wait until 1/3 of the static level has been pumped off.
How long this takes depends on the nominal size.
Pause the pumping process at the disposal vehicle.
Switch on the shredder-mix pump
Wait until the separator contents have been homogenised
sufficiently. The period of time that this take depends on
the nominal size
.
The shredder mix pump switches off automatically after
the end of the „Mixing-Cleaning" program.
The "Partially fill valve" program section starts up auto-
matically if the On delay has expired. This can occur at
the same time as the start/end of the "Mixing-Cleaning"
program, or also while this program is running. It is even
possible to set a start after the end of the "Mixing-Clean-
ing" program, namely if the duration of the On delay is
longer than the duration of the "Mixing-Cleaning" pro-
gram.