Area / version
Standard
Cold water
requirements
(up to sta-
tic level in l)
100% grease
layer thick-
180
ness (mm)
Empty
weight (kg)
Electrical connection values
Operating voltage
Mains frequency
Pump capacity P1/P2
Nominal current range
Protection class (pump)
Required fuse protection
Protection class
Max. pumping height
Max. pumping capacity
(Permanent) temperature of conveyed material
Tightening torque
Description
PT-screw 100x30 A2
Attachment clamp
Pipe clamp D=84
Pipe clamp D=120
PT-screw KB60x30 WN 1411
PT-6 hexagon screw K80x40
WN 1447
Door hinge screw A2 bright
6x40
Technical interfaces
Data
Cable type
Remote control
LIYCY 3x0.34 mm²
* Depending on the version
54 / 132
Direct
235
180
235
355
360
Data
Use
Torque Nm
Inspection window
Mounting cover
Direct disposal pipe
8-10
Suction pipe
8-10
Flushing nozzles
4.5 ±0.5
Hand lever
5.5 ±0.5
Actuator on valve
4.5 ±0.5
Shield-
ing
Yes
Installation and operating instructions
Mix
AutoMix
2600
180
235
180
410
410
Drive
Stan-
dard
7
T50
3
ISK 10mm
Socket
13 mm
Socket
13 mm
T30
Socket
13mm
T30
Type of con-
Cable
nection
length
Control line
15 m
Mix & Pump
235
180
235
180
415
Value
400 V
50 Hz
3.6 / 3.0 kW
2.5 - 6 A
IP 55
C 16
I
17 m
60 m
/h
3
max. 40 °C
Direct
Mix
Auto
Mix &
Mix
Pump
max.
Extension/alternative
length
100 m
None /
Replace with a suitable
length
AutoMix
& Pump
235
420
Auto
Mix &
Pump
016-673