Refilling the tank
Open the cold water valve.
Wait until the water level has reached the static level
stop cold water supply.
Place the control valve in the RINSE position (arrow to
the left).
This is the lever position for normal opera-
tion.
Disconnect the suction hose of the disposal vehicle from
the Storz-B coupling.
Record the disposal in the log book.
Disposal procedure is completed.
6.7
EasyClean free Auto Mix & Pump version
Carry out disposal
Partial emptying
Connect the suction hose of the disposal vehicle to the
Storz B coupling
.
Press the START/STOP button to open the | Start auto-
matic operation | menu, then confirm with OK:
The program step | Part-empty | starts automatically.
When this has finished, the following program step is exe-
cuted automatically, see below
Mix
The program step | Mix | is executed automatically.
Wait until the separator contents have been homogenised
sufficiently. How long this takes depends on the nominal
size.
74 / 132
,
.
Installation and operating instructions
016-673