Filling with cold water
Start the cold water supply.
Wait until the water level has reached the static level
and then stop cold water supply.
(If there is no refill inlet available, use a water hose to fill
the tank.)
Re-close the service access.
Record the disposal in the log book.
Disposal procedure is completed.
6.3
EasyClean free Direct version
Carry out disposal
Connect the suction hose of the disposal vehicle to the
Storz-B coupling.
Start the pumping process at the disposal vehicle.
Clean the inside walls of the tank (as far as required) while
pumping off
Wait until 1/3 of the static level has been pumped off.
How long this takes depends on the nominal size.
Open the service access cover during pumping off.
Use a water hose to clean the inside walls of the tank.
Tank has been pumped empty
As soon as the tank has been pumped empty (slurping
noises)
, end the pumping off process by the disposal
vehicle.
Fill up with cold water
Start cold water supply.
Wait until the water level has reached the static level
stop cold water supply.
(If there is no refill inlet available, use a water hose to fill
the tank.)
If necessary, seal the service access cover again.
Record the disposal in the log book.
Disposal procedure is completed.