Carry out disposal
Partial emptying
Connect the suction hose of the disposal vehicle to the
Storz-B coupling.
Turn the control valve to the DRAIN position (arrow to the
right).
Start manual operation at the control unit.
Wait until 1/3 of the static level has been pumped off.
How long this takes depends on the nominal size.
Pause manual operation at the control unit.
Mix
Turn the control valve to the RINSE position (arrow to the
left).
Start manual operation at the control unit.
Wait until the separator contents have been homogenised
sufficiently. How long this takes depends on the nominal
size. The times in the table shown below can be used as
guide values.
Pause manual operation at the control unit.
Pump off
Turn the control valve to the DRAIN position (arrow to the
right).
Start manual operation at the control unit.
Wait until the pump stops running.
End the pumping process at the disposal vehicle.
Duration of pumping process:
The values can be adjusted to the respective require-
ments using the Kessel NFC app.
Download it from the app stores.
016-673
Installation and operating instructions
73 / 132