INSTALLATION INSTRUCTIONS
CONTROL PANEL 3010 614
Control Panel 3010 614 is intended for the Alde Compact
3010 boiler.
The Control Panel should be located at least 3,3 foot (1
meter) above the floor, but not too close to the ceiling.
Nor should it be enclosed, located on an outer wall or
close to objects which radiate heat, for example, CD play-
ers, refrigerator and lamps, as this can give incorrect tem-
perature. The area behind the panel should be well ven-
tilated. If the room temperature on the panel is affected
nevertheless, an external sensor should be connected to
the panel.
Make a hole for the panel as shown in figure C. Screw
down the panel and push the front part on. Clip on the
cables to avoid wear on the terminal strip of the panel.
86 mm
3,5"
A.
B.
9 mm
3,5"
76 mm
C.
73 mm
3"
2,8"
R3(4x)
22
38,5 mm
1,5"
CABLE CONNECTION
CONTROL PANEL 3010 614
Connect accessories to the Control Panel as shown in the dia-
gram below.
NOTICE
Do not clamp or bind 12 V cables or sensor cables
together with 120 V cables. It is preferable not to
place the cables close to each other. If the cables
are bundled, the risk of shutdown increases.
Back of Control Panel
Remote sensor, white (G)
External sensor, blue (F)
Load monitor, green (E)
Pump signal (B)
1
6