OPERATING INSTRUCTIONS
The KT4M pump has been designed and developed
to operate in environments with atmospheres that
are not potentially explosive and with fluids with a
high percentage of bentonite, whose recommended
maximum value of density is equal to ~ 45 sec.
Marsh cone (test carried out according to UNI 11152)
and at a maximum temperature of 40°C.
The maximum size of solid particulate in the fluid
sucked in by the pump must be 4 mm.
Other liquids can be used only upon formal approval
by the Technical Office or Customer Service
Department.
7.1
Bentonite temperature
The maximum permissible bentonite temperature
is 30 °C. However, the pump can be used with
bentonite up to a temperature of 40 °C, but only for
short periods. In this case, it is best to consult the
Technical or Customer Service Departments.
7.2
Maximum pressure and flow rate
The rated specifications stated in our catalog are the max.
that can be obtained by the pump. Independently of the
power used, the maximum pressure and rpm indicated in the
specification label can never be exceeded unless upon prior
formal authorization by our Technical or Customer Service
Departments.
7.3
Minimum rotating speed
The minimum permissible speed for these types of pumps is
100 rpm at the bend shaft.
Any rotating speed other than that indicated in the
performance table (see chapter 5) must be expressly
formally authorized by our Technical or Customer Service
Departments.
7.4
Sound emission
The sound pressure detection test was performed according
to Directive 2000/14 of the European Parliament and Council
(Machinery Directive) and EN-ISO 3744-1995 with class 1
instrumentation.
A final detection of sound pressure must be performed on the
complete machine/system.
Should the operator be located at a distance of less than
1 meter, he will have to use appropriate hearing protection
according to current regulations.
7.5
Vibration
The detection of this value shall be carried out only with the
pump set up on the plant and at the performance declared by
the customer. Values must be in accordance with regulations.
7.6
Brands and types of oils recommended
The pump is supplied with oil suitable for room temperatures
from 0 °C to 30 °C.
Some types of recommended oil are indicated in the table
below, these oils have additives to increase corrosion
resistance and fatigue resistance (DIN 51517 part 2).
Alternatively you can also use Automotive Gear SAE 85W-90
oil for gearing lubrication.
Manufacturer
Lubricant
AGIP ACER220
Aral Degol BG 220
BP Energol HLP 220
CASTROL HYSPIN VG 220
CASTROL MAGNA 220
Falcon CL220
ELF POLYTELIS 220
REDUCTELF SP 220
NUTO 220
TERESSO 220
FINA CIRKAN 220
RENOLIN 212
RENOLIN DTA 220
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level and top up if necessary.
Using the oil dipstick pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing:
the oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in Fig. 14 chapter 11.
The quantity required is ~ 2 litres.