Changing the Floor Tool Blades
!
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY
Unscrew the four knobs securing the blade holder (Fig.43).
Remove the blade holder (Fig.44).
Replace the Squeegee blades using (606261) replacement blade set (Fig.45), fitting the blades on to the moulded
location lugs.
Refitting the Floor Tool Blades
1. Floor-tool main body
2. Blade carrier
3. Rear blade
4. Front blade (slotted)
5. Retaining Knobs x 4
Use Genuine NUMATIC spare parts.
Replacement Blade Set (606261)
MAINTENANCE
Fig.41
Fig.42
Fig.43
Fig.47
Fig.46
1
2
3
4
To change the floor-tool, firstly swing the floor-tool clear of the
machine (Fig.41).
Undo the two floor-tool retaining knobs (Fig.42).
Fig.44
Refit the blade holder, retain using the two outer knobs.
(Fig.46)
Ensure the slotted blade goes to the front of the
floor-tool (Fig.47).
Note:
The blades are designed to be reversible, thus
extending their useful working life.
Refit the floor-tool using the two central knobs to
the floor-tool.
Refer to Page 9 for fitting instructions.
5
38
!
Fig.45