Changing the Floor Tool Blades
!
Always ensure that the machine is switched off prior to any maintenance.
Lower the floor tool then unscrew the retaining knobs and slide it off the holding bracket.
Rinse the floor tool assembly with clean water and refit.
Remove floor tool.
Turn the floor tool over.
Periodically the floor tool blades should be examined and checked for wear and damage.
Replacement is a reversal of the removal process.
Floor Tool Overview
1. Retaining pins x 4
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Floor tool main body
NOTE: The blades are designed to be
reversible, thus extending their useful
working life.
26
www.numatic.co.uk
Remove four retaining pins.
Separate the blade from the carrier.
1
2
3
4
5
Peel away blades.
!