ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO
The floor-tool
The TT range is provided with the aluminium floor-tool shown.
To clean the floor-tool, remove securing-pin and disconnect the lifting strap and remove the floor-tool securing pin pull-free the floor-
tool from the rear of the machine. Rinse the floor-tool assembly with clean water and refit.
34
Periodically the floor-tool blades should be examined and checked for wear and damage.
The blade removal is easy. Simply start by removing the four retaining pins (Fig.33), turn the floor-tool over and separate the blade
carrier from the body (Fig.34). Peel away the blades from their locating lugs (Fig.35) and examine or renew as required. Replacement is
a reversal of the removal process.
Floor-tool overview
1. Floor-tool main body
4. Front blade (slotted)
5. Retaining pins x 4
The blades are designed to be reversible, thus extending their useful working life.
ANY MAINTENANCE
2. Rear blade
3. Blade carrier
33
35