Setting or changing the parameter value
► Press [▲] / [▼] until the requested parameter value is
displayed (→ 8.2.3 Numerical entries).
Acknowledgement of the set parameter value
► Press [Enter/►] until the parameter abbreviation no longer
flashes and the indicator PRG has disappeared�
> The new parameter value is indicated and effective�
Return to the RUN mode
► Press [Enter/►] for about 3 s or wait for the time-out function
(approx� 15 s)�
> The unit is again in the RUN mode, the current value is
indicated�
8.2 Notes on programming
8.2.1 RUN mode
8.2.2 Time Out Function
If during programming no pushbutton is pressed for approx� 15 s, this is seen as a
cancellation�
Parameter changes which are not acknowledged with [Enter/►] are rejected.
The previously set parameter value is restored and remains effective for the
monitoring functions�
8.2.3 Numerical entries
► Press [▲] or [▼] and hold it.
The smallest decade becomes active and is counted up or down depending on the
selected pushbutton (e�g� 1, 2, 3,���0)� Then comes the next decade, etc�
20
256
Notice de montage et d'exploitation – Entraînements pour élévateurs à godets – Série X..e
During programming the unit internally remains in the RUN mode (RUN
indicator visible)�
This means that until a new value is acknowledged with [Enter/►], the
unit carries out its monitoring function on the basis of the previously set
parameters and switches the relay and transistor outputs accordingly�
The monitoring function of the monitor is deactivated by continuously
pressing [Enter/►] in the RUN mode. The deactivation is effective as long
as the button is pressed�
1
CH1
RUN
1
CH1
RUN
1
CH1
RUN
0.0
DT1
CH1
RUN
0.0
DT1
CH1
RUN
0.0
CH1
RUN PRG
DT1
0.0
DT1
CH1
RUN PRG
0.0
DT1
CH1
RUN PRG
0.0
CH1
RUN PRG
DT1
15.0
DT1
CH1
RUN PRG
15.0
DT1
CH1
RUN PRG
15.0
CH1
RUN
DT1
15.0
DT1
CH1
RUN
15.0
DT1
CH1
RUN
15.0
CH1
RUN
DT1
1665
RPM
CH1
RUN
1665
RPM
CH1
RUN
1665
RPM