6.2.2 DC supplies
► The SELV criteria (safety extra-low voltage) must be met for the DC supply�
► The DC supply cable L+ (terminal 2) must be protected externally with a 315
mA time-lag fuse (5 x 20 mm or similar)�
The DC supply terminals are directly connected to the sensor supply terminals�
6.3 Inputs
6.3.1 Connection of the sensors (In1)
DC PNP to FR-1
BN
BK
BU
DC quadronorm to FR-1
WH
BK
Connection of the sensors
The connection of mechanical switch contacts is not recommended since
they tend to bounce and produce faulty pulses�
The terminals 5/6 can be used for the sensor supply or for the reset inputs (only
F���-x)�
6.3.2 Reset inputs (reset 1 and 2)
The start-up delay can be started or a saved error can be reset via the reset inputs
(terminals 17/18)�
► The internal +24 V DC voltage (terminal 5) or an external +24 V DC voltage is
connected with terminal 17 or 18 via a closing contact�
► If an external voltage is used, the negative reference point of this voltage must
be connected to terminal 1 of the monitor�
When the contact is opened (+ 24 V DC no longer applied), the start-up delay or
the memory reset starts�
Notice de montage et d'exploitation – Entraînements pour élévateurs à godets – Série X..e
DC NPN to FR-1
BN
5
BK
4
BU
6
NAMUR up to 25 V to FR-1
BN
5
BU
4
Documentation fournisseur
AC/DC to FR-1
BN
5
10
BU
6
NAMUR 8�2 V to FR-1 N
BN
10
BU
6
11
UK
5
4
6
5
11